This guide covers specific methods of failure mode classifications and analysis for shielded power cables rated 5 kV through 46 kV. Keywords: cable failure, chemical failure mode, distribution material failure report, electrical failure mode, general aging failure mode, IEEE 1511.1, thermal failure mode.
Choose an application
This guide provides a summary of the methods for detection, mitigation, and control of concentric neutral corrosion in medium-voltage, unjacketed, underground distribution cable installed direct buried or in conduit. The causes of corrosion in cable concentric neutral wires and straps and the methods available to detect this corrosion are described. The purpose of the concentric neutral and the consequences of significant loss of the concentric neutral are discussed. Recommendations are made for the mitigation and control of the cable concentric neutral corrosion.
Choose an application
Choose an application
Superseded by 576-2000. A guide to installation, splicing, termination, and field-proof testing of cable systems is provided. The aim is to avoid premature cable failure due to improper installation and mechanical damage during installation, and to provide a reference that can be specified for cable installations. This standard is not intended to be a design document; many of the problems of installation can be avoided by designing cable layouts with the installation limits of this recommended practice.
Choose an application
The guide is to aid wire and cable manufacturers in the study of smoke generation characteristics of materials used in products. The two test methods looked at are the NBS method, where measurement is made of the attenuation of a light beam by the smoke, and the Arapahoe method, where smoke and char are measured gravimetrically under dynamic conditions.
Choose an application
Various field test methods that are currently available or under development are listed in this guide. The guide covers shielded, insulated power cable systems rated 5 kV and above. The guide describes the tests and gives advantages and disadvantages, suggested applications, and typical results. Complete guides covering some of the test methods listed are available in the form of IEEE 400 "point" documents. Keywords: field testing, IEEE 400, power cable system.
Choose an application
Various field test methods that are currently available or under development are listed in this guide. The guide covers shielded, insulated power cable systems rated 5 kV and above. The guide describes the tests and gives advantages and disadvantages, suggested applications, and typical results. Complete guides covering some of the test methods listed are available in the form of IEEE 400 "point" documents.
Choose an application
The recommended practices and procedures for direct voltage acceptance and maintenance testing of shielded, laminated dielectric insulated power cable systems rated 5 kV and above are presented in this guide. It applies to all types of laminated power cable systems such as paper insulated, lead covered, pipe-type, and pressurized cables that are intended for the transmission or distribution of electric power. The tabulated test levels assume that the cable systems have an effectively grounded neutral system or a grounded metallic shield.
Choose an application
Very low frequency (VLF) withstand and other diagnostic tests and measurements that are performed using VLF energization in the field on shielded power cable systems are described in this guide. Whenever possible, cable systems are treated in a similar manner to individual cables. Tables are included as an aid to identifying the effectiveness of the VLF ac voltage test for various cable system insulation problems. Keywords: cable fault locating, cable system testing, cable testing, condition assessment, dielectric spectroscopy, grounding, hipot testing, IEEE 400.2, partial discharge testing, proof testing, safety, tangent delta testing, very low frequency testing, VLF ac voltage testing.
Choose an application
Very low frequency (VLF) withstand and other diagnostic tests and measurements that are performed using VLF energization in the field on shielded power cable systems are described in this guide. Whenever possible, cable systems are treated in a similar manner to individual cables. Tables are included as an aid to identifying the effectiveness of the VLF ac voltage test for various cable system insulation problems.