General guidelines toward the preparations of a functional specification of transmission fixed-series capacitor (FSC) banks using overvoltage protection based on three technologies are provided. The three technologies are:- metal oxide varistors-metal oxide varistors with a forced-triggered bypass gaps, and thyristor protected series capacitors- thyristor protected series capacitor. This guide does not apply comprehensively to thyristor-controlled series capacitors.
Choose an application
Superseded by 18-2002. Capacitors rated 216 V or higher, 2.5 kvar or more, and designed for shunt connection to alternating-current transmission and distribution systems operating at a nominal frequency of 50 or 60 Hz are considered. Service conditions, ratings, manufacturing, and testing are covered. A guide to application and operation of power capacitors is included.
Choose an application
Capacitors rated 216 V or higher, 2.5 kvar or more, and designed for shunt connection toalternating-current transmission and distribution systems operating at a nominal frequency of 50 Hzor 60 Hz, within the guidelines of IEEE Std 1036-1992, are considered.
Choose an application
The protection of shunt power capacitor banks and filter capacitor banks are discussed in this guide. The guidelines for reliable application of protection methods intended for use in many shunt capacitor bank designs are included. Also, a detailed explanation of the theory of unbalance protection principles is provided. Discussions on the protection of pole-mounted capacitor banks on distribution circuits or capacitors connected to the terminals of rotating machines are not included as they are outside the scope of this standard. Keywords: bank configuration, externally fused, filter bank, fuseless, IEEE C37.99, internally fused, overcurrent, overvoltage, relay, shunt capacitor bank, unbalance protection.
Choose an application
Switched capacitor circuits --- Switched capacitor filters --- Design.
Choose an application
The protection of shunt power capacitor and filter banks are covered. Guidelines for reliable applications of protection methods intended for use in many shunt capacitor applications and designs are included. The protection of pole-mounted capacitor banks on distribution circuits and the application of capacitors connected directly to routing apparatus are not included.
Choose an application
This guide applies to the protection of shunt power capacitor banks and filter capacitor banks. Included are guidelines for reliable applications of protection methods intended for use in many shunt capacitor applications and designs. The guide does not include the protection of pole mounted capacitor banks on distribution circuits or capacitors connected to rotating machines.
Choose an application
Ratings, construction, and testing of dead-front control switchboards containing, but not limited to, devices such as switches, control devices, instrumentation, metering, monitoring, protective and auxiliary relays, and regulating devices and accessories are covered. Switchboards for the control and protection of apparatus used for or associated with power generation, conversion, transmission, and distribution are included, but the standard is not limited to these. Industrial controls, communication equipment, switchboards for use on board ships, Class 1E switchboards for use in nuclear generating stations, and human factors are not considered.
Choose an application
Choose an application
Provided in this guide for low frequency dielectric testing for distribution, power, and regulating transformers are background on various low frequency test methods as well as guidance on how to conduct and interpret the results. Common pitfalls to avoid are presented along with compiled guidance on interpreting the results and possible methods for correcting test issues.