Book
"C37.20.2a-2020 - IEEE Standard for Metal-Clad Switchgear--Amendment 1: Control and Secondary Circuits and Devices, and All Wiring"
Author:
ISBN: 1504465644 9781504465649 Year: 2020 Publisher: IEEE

Loading...
Export citation

Choose an application

Bookmark

Abstract


Book
"C37.250-2020 - IEEE Guide for Engineering, Implementation, and Management of System Integrity Protection Schemes"
Author:
ISBN: 1504465598 9781504465595 Year: 2020 Publisher: IEEE

Loading...
Export citation

Choose an application

Bookmark

Abstract


Book
"C37.48-2020 - IEEE Guide and Tutorial for the Application of High-Voltage (> 1000 V) Fuses and Accessories - Redline"
Author:
ISBN: 1504472128 9781504472128 Year: 2020 Publisher: IEEE

Loading...
Export citation

Choose an application

Bookmark

Abstract


Book
"C62.11-2020 - IEEE Standard for Metal-Oxide Surge Arresters for AC Power Circuits (>1 kV)"
Author:
ISBN: 1504467086 9781504467087 Year: 2020 Publisher: IEEE

Loading...
Export citation

Choose an application

Bookmark

Abstract


Book
"C37.21a-2020 - IEEE Standard for Control Switchboards--Amendment 1: Control and Secondary Circuits and Devices, and All Wiring"
Author:
ISBN: 1504465725 9781504465724 Year: 2020 Publisher: IEEE

Loading...
Export citation

Choose an application

Bookmark

Abstract


Book
Theory and design of switching circuits
Authors: ---
ISBN: 9780273011118 0273011111 Year: 1960 Publisher: London: Pitman,

Loading...
Export citation

Choose an application

Bookmark

Abstract


Book
ASA C37.11-1957 : ASA American National Standard Requirements for Power Circuit Breaker Control
Author:
ISBN: 1504404750 Year: 1957 Publisher: [Place of publication not identified] : IEEE,

Loading...
Export citation

Choose an application

Bookmark

Abstract

This standard applies to all types of electrically controlled indoor and outdoor power circuit breakers, including circuit breakers in switchgear cubicles and in metal-clad switchgear, having an interrupting rating of 50 megavolt-amperes (mva) or higher and a voltage rating above 1500 volts. This standard applies for any source of circuit breaker operating energy, such as solenoid, motor, spring, compressed gas, etc, for any type of operating mechanism and for both a-c and d-c control power.


Book
ANSI/IEEE Std C37.04-1979 : IEEE Standard Rating Structure for AC High-Voltage Circuit Breakers Rated on a Symmetrical Current Basis
Author:
ISBN: 0738110329 Year: 1980 Publisher: Piscataway, NJ : IEEE,

Loading...
Export citation

Choose an application

Bookmark

Abstract

A rating structure for AC high-voltage circuit breakers rated on a symmetrical current basis is established. The rating structure applies to indoor and outdoor types of AC high-voltage circuit breakers rated above 1000 V. Service conditions, construction, and nameplate markings are also considered.


Book
IEEE Std C37.21-2005 (Revision of IEEE Std C37.21-1985) : IEEE Standard for Control Switchboards
Authors: --- ---
ISBN: 0738147508 0738147516 Year: 2005 Publisher: New York : IEEE,

Loading...
Export citation

Choose an application

Bookmark

Abstract

This standard covers ratings, construction, and testing of dead-front control switchboards containing but not limited to devices such as switches, control devices, instrumentation, metering, monitoring, alarms, annunciators, protective and auxiliary relays, and regulating devices and accessories. It includes, but is not specifically limited to, switchboards for the control and protection of apparatus used for or associated with power generation, conversion, transmission, and distribution. Types of switchboards may include control, vertical, dead-front, enclosed, dual, or duplex switchboards. Other construction types include control desks, consoles, benchboards, dual or duplex benchboards, fixed rack, cabinet, and swing rack cabinets. It does not apply to industrial controls, communication equipment, switchboards for use on board ships, or Class 1E switchboards for use in nuclear generating stations.


Book
IEEE Guide for Metal-Enclosed Bus and Calculating Losses in Isolated-Phase Bus
Author:
ISBN: 0738110590 Year: 1987 Publisher: New York : Institute of Electrical and Electronics Engineers (IEEE),

Loading...
Export citation

Choose an application

Bookmark

Abstract

Interpretations are available at: http://standards.ieee.org/reading/ieee/interp/C37.23-1987.html This IEEE Standards product is part of the C37 family on Switchgear, Substations and Protective Relays. Assemblies of metal-enclosed conductors and their associated interconnections, enclosures, supporting structures, switches, and disconnecting links are addressed. Ratings, tests, construction, miscellaneous accessories, and loss calculation for isolated-phase buses are covered. Specifically excluded are busways or bus assemblies for distribution of electric power less than 600 V, which consist of enclosed sectionalized prefabricated bus bars or associated structures and fittings, such as feeder busways (indoor or outdoor), plug-in busways (indoor only), and bus assemblies utilized at voltages in excess of 38.0 kV.

Listing 1 - 10 of 161 << page
of 17
>>
Sort by