Listing 1 - 10 of 161 | << page >> |
Sort by
|
Choose an application
Choose an application
Choose an application
Choose an application
Choose an application
Choose an application
Choose an application
This standard applies to all types of electrically controlled indoor and outdoor power circuit breakers, including circuit breakers in switchgear cubicles and in metal-clad switchgear, having an interrupting rating of 50 megavolt-amperes (mva) or higher and a voltage rating above 1500 volts. This standard applies for any source of circuit breaker operating energy, such as solenoid, motor, spring, compressed gas, etc, for any type of operating mechanism and for both a-c and d-c control power.
Choose an application
A rating structure for AC high-voltage circuit breakers rated on a symmetrical current basis is established. The rating structure applies to indoor and outdoor types of AC high-voltage circuit breakers rated above 1000 V. Service conditions, construction, and nameplate markings are also considered.
Choose an application
This standard covers ratings, construction, and testing of dead-front control switchboards containing but not limited to devices such as switches, control devices, instrumentation, metering, monitoring, alarms, annunciators, protective and auxiliary relays, and regulating devices and accessories. It includes, but is not specifically limited to, switchboards for the control and protection of apparatus used for or associated with power generation, conversion, transmission, and distribution. Types of switchboards may include control, vertical, dead-front, enclosed, dual, or duplex switchboards. Other construction types include control desks, consoles, benchboards, dual or duplex benchboards, fixed rack, cabinet, and swing rack cabinets. It does not apply to industrial controls, communication equipment, switchboards for use on board ships, or Class 1E switchboards for use in nuclear generating stations.
Choose an application
Interpretations are available at: http://standards.ieee.org/reading/ieee/interp/C37.23-1987.html This IEEE Standards product is part of the C37 family on Switchgear, Substations and Protective Relays. Assemblies of metal-enclosed conductors and their associated interconnections, enclosures, supporting structures, switches, and disconnecting links are addressed. Ratings, tests, construction, miscellaneous accessories, and loss calculation for isolated-phase buses are covered. Specifically excluded are busways or bus assemblies for distribution of electric power less than 600 V, which consist of enclosed sectionalized prefabricated bus bars or associated structures and fittings, such as feeder busways (indoor or outdoor), plug-in busways (indoor only), and bus assemblies utilized at voltages in excess of 38.0 kV.
Listing 1 - 10 of 161 | << page >> |
Sort by
|