This document presents procedures and test voltage values for acceptance and maintenance testing of ESP cable systems. It applies to cable systems rated 3000 V and 5000 V. It is intended to apply only to this special purpose cable.
Choose an application
Withdrawn Standard. Withdrawn Date: Dec 09, 1997. No longer endorsed by the IEEE. Revision of IEEE Std 1017-1985 Procedures and test-voltage values for acceptance and maintenance testing of electrical submersible pump (ESP) cable systems are presented. This recommended practice applies to cable systems rated 3000 V and 5000 V and is intended only for this special-purpose cable. The intent is to provide uniform test procedures an guidelines for evaluation of the test results.
Choose an application
Procedures and test voltage values for acceptance and maintenance testing of electrical submersible pump (ESP) cable systems are presented. This recommended practice applies to cable systems rated 3 kV and 5 kV (phase to phase) and is intended only for this special-purpose cable. The intent is to provide uniform test procedures and guidelines for evaluation of the test results.
Choose an application
Procedures and test voltage values for acceptance and maintenance testing of electric submersible pump (ESP) cable systems are presented. This recommended practice applies to cable systems rated 3 kV and 5 kV (phase to phase) and is intended only for this special-purpose cable. The intent is to provide uniform test procedures and guidelines for evaluation of the test results.
Choose an application
Procedures and test voltage values for acceptance and maintenance testing of electric submersible pump (ESP) cable systems are presented. This recommended practice applies to cable systems rated 3 kV and 5 kV (phase to phase) and is intended only for this special-purpose cable. The intent is to provide uniform test procedures and guidelines for evaluation of the test results.
Choose an application
Minimum requirements for the design, construction, manufacturing, testing, purchasing, and application of electric submersible pump (ESP) cable are presented. The cable is round or flat, with ethylene-propylene rubber insulation, nitrile jacket, ethylene-propylene diene monomer (EPDM) jacket or lead sheath, and armor. These cables are for voltages not exceeding 3 kV or 5 kV (phase to phase) and conductor temperatures not exceeding 140 ºC (284 ºF) for nitrile or a maximum of 232 ºC (450 ºF) for EPDM jacket or lead sheath cable. Conductors, insulation, barrier (optional), assembly with or without jacket, armor, requirements for testing by the manufacturer, and cable ampacity are all covered in the document.
Choose an application
Minimum requirements for the design, construction, manufacturing, testing, purchasing, and application of electric submersible pump (ESP) cable are presented. The cable is round or flat, with ethylene-propylene rubber insulation, nitrile jacket, ethylene-propylene diene monomer (EPDM) jacket or lead sheath, and armor. These cables are for voltages not exceeding 3 kV or 5 kV (phase to phase) and conductor temperatures not exceeding 140 ºC (284 ºF) for nitrile or a maximum of 232 ºC (450 ºF) for EPDM jacket or lead sheath cable. Conductors, insulation, barrier (optional), assembly with or without jacket, armor, requirements for testing by the manufacturer, and cable ampacity are all covered in the document.
Choose an application
This recommended practice establishes requirements for a three-conductor round-type oil well cable used in supplying three-phase ac electric power to submersible pump motors. Cables meeting the requirements of the recommended practice should be rated for voltages not exceeding 3 kV and for ambient temperatures not exceeding 167 F (75 C). Use of cable above rated temperature can cause premature deterioration of the insulation. The cable defined herein is not recommended for installation below a temperature of 14 F (-10 C). Voltage ratings are nominal phase-to-phase ratings.
Choose an application
Minimum requirements for the construction, manufacturing, purchasing, and application of electric submersible pump cable are presented. The cable is round or flat, with polypropylene rubber insulation, nitrile jacket, and armor. These cables are for voltages not exceeding 3 kV or 5 kV (phase to phase) and conductor temperatures not exceeding 96 degC (205 degF) for nitrile or a maximum of -10 degC (14 degF). Conductors, insulation, assembly and jacket, armor, requirements for testing by the manufacturer, and cable ampacity are covered.
Choose an application
Minimum requirements for the design, construction, manufacturing, testing, purchasing, and application of electric submersible pump cable are presented. The cable is round or flat, with polypropylene rubber insulation, nitrile or polyethylene jacket, and armor. These cables are for voltages not exceeding 3 kV or 5 kV (phase to phase) and conductor temperatures not exceeding 96°C (205°F) maximum for nitrile or a maximum minimum of -10°C (14°F) minimum. Conductors, insulation, assembly and with or without jacket, armor, requirements for testing by the manufacturer, and cable ampacity are all covered in the document.