Goals for the design of electrical systems that include both linear and nonlinear loads are established in this recommended practice. The voltage and current waveforms that may exist throughout the system are described, and waveform distortion goals for the system designer are established. The interface between sources and loads is described as the point of common coupling and observance of the design goals will reduce interference between electrical equipment.This recommended practice addresses steady-state limitations. Transient conditions exceeding these limitations may be encountered. This document sets the quality of power that is to be provided at the point of common coupling. This document does not cover the effects of radio-frequency interference; however, guidance is offered for wired telephone systems.
Choose an application
Provided in this recommended practice are calculation methods for conservatively evaluating the feasibility for an existing installed dry-type or liquid immersed transformer, to supply nonsinusoidal load currents as a portion of the total load. Also provided is necessary application information to assist in properly specifying a new transformer expected to carry a load, a portion of which is composed of nonsinusoidal load currents. A number of examples illustrating these methods and calculations are presented. Reference annexes provide a comparison of the document calculations to calculations found in other industry standards. Suggested temperature rise calculation methods are detailed for reference purposes.
Choose an application
Harmonic studies and analysis of industrial and commercial power systems are described. The basic concepts involved in such studies are described first. This is followed by a discussion of how to determine the need for a harmonic study, how to assemble the required data, how to recognize potential problems, and how to implement corrective measures.
Choose an application
Guidance for controlling or modifying the inductive environment and the susceptibility of affected wire line telecommunications facilities in order to operate within the acceptable levels of steady-state or surge induced voltages of the environmental interface (probe wire) defined by IEEE Std 776(TM) is provided in this Recommended Practice. Procedures for determining the source of the problem are given. Mitigation theory and philosophy are discussed, and mitigation devices are described. The application of typical mitigation apparatus are addressed. Advice for determining the best engineering solution is offered, and general safety considerations are discussed.
Choose an application
Choose an application
Choose an application
Listing 1 - 10 of 1781 | << page >> |
Sort by
|