The scope of this recommended practice covers the application of center grounded applied voltage but not voltage wave shapes in which either the positive or negative peak voltage is at ground potential.
Choose an application
Various field test methods that are currently available for or have been developed are listed in this guide. The guide covers shielded, insulated power cable systems rated 5 kV and above. The guide also describes the tests and gives advantages and disadvantages, suggested applications, and typical results. Complete guides covering some of the test methods listed are available in the form of IEEE 400 "point" documents.
Choose an application
Superseded. Information on the equipment needed and the methods that can be used to clean contaminated electrical insulators are presented. The intent is to document the state of the art for cleaning insulators (excluding nuclear contaminants) of all types. Energized and de-energized systems are considered. The standard does not prescribe specific procedures, but rather reflects the experience of many individuals who have safely cleaned contaminated insulators.
Choose an application
Superseded by 957-2005 Procedures for cleaning contaminated electrical insulators (excluding nuclear, toxic, and hazardous chemical contaminants) of all types, using various equipment and techniques, are provided.
Choose an application
Electric wire, Insulated --- Plastic coating --- Patents --- Patents
Choose an application
Nuclear power plants --- Electric wire, Insulated --- Electric equipment. --- Defects.
Choose an application
These specifications apply to the insulation of electric wire and cable of the grade known as 30 per cent Hevea rubber.
Rubber, Artificial. --- Electric cables--Insulation. --- Electric wire, Insulated. --- Electric cables --- IEEE Standards --- Insulation.
Choose an application
Guidance for the planning, permitting, design, equipment specification, installation, commissioning, operation, and maintenance of gas-insulated transmission lines is provided in this project. Only technical aspects are addressed in this guide. Commercial and legal issues associated with gas-insulated transmission lines are not considered. This guide applies to ac transmission lines rated for maximum operating voltage of 72.5 kV and higher.
Electric cables --- Electric insulators and insulation. --- Electric wire, Insulated. --- Gas insulation.
Choose an application
Nuclear power plants --- Electric wire, Insulated --- Polyvinyl chloride. --- Electric equipment. --- Defects.