Listing 1 - 10 of 556 | << page >> |
Sort by
|
Choose an application
Choose an application
This guide provides general recommendations for performing maintenance work on energized power-lines. It is not intended to include all of the proven, practical methods and procedures; however, these selected comprehensive recommendations are based on sound engineering principles, engineering safety considerations, and decades of field experiences by many utilities. Included are technical explanations as required to cover: certain laboratory testing of tools and equipment; field maintenance and care of tools and equipment; work methods for the maintenance of energized lines and for persons workings in the vicinity of energized lines.
Choose an application
Uniform procedures are established for manual and automatic measurement of audible noise from overhead transmission lines. Their purpose is to allow valid evaluation and comparison of the audible noise performance of various overhead lines. Definitions are provided, and instruments are specified. Measurement procedures are set forth, and precautions are given. Supporting data that should accompany the measurement data are specified, and methods for presenting the latter are described.
Choose an application
Superseded by 516-2003. General recommendations for performing maintenance work on energized power lines are pro-vided. Technical explanations as required to cover certain laboratory testing of tools and equipment, field maintenance and care of tools and equipment, and work methods for the maintenance of energized lines and for persons working in the vicinity of energized lines are included.
Choose an application
This guide provides the general recommendations for performing maintenance work on energized power lines. It is not intended to include all of the proven practical methods and procedures, however, these selected comprehensive recommendations are based on sound engineering principles, engineering safety considerations, and field experience by many utilities. Included are technical explanations as required to cover certain laboratory testing of tools and equipment, in-service inspection, maintenance and care of tools and equipment, and work methods of the maintenance of energized lines for persons working in vicinity of power lines.
Choose an application
General recommendations for the selection of methods and equipment found to be effective and practical for grounding during the stringing of overhead trasmission line conductors and overhead ground wires are provided. The guide is directed to transmission voltages only. The aim is to present in one document sufficient details of present day grounding practices and equipment used in effective grounding and to provide electrical theory and considerations necessary to safeguard personnel during the stringing operations of transmission lines.
Choose an application
Uniform procedures are established for manual and automatic measurement of audible noise from overhead transmission lines. Their purpose is to allow valid evaluation and comparison of the audible noise performance of various overhead lines. Definitions are provided, and instruments are specified. Measurement procedures are set forth, and precautions are given. Supporting data that should accompany the measurement data are specified, and methods for presenting the latter are described.
Choose an application
A generic specification, including design and testing, for transmission modular restoration structure components used by electric utilities is provided.
Choose an application
Choose an application
Listing 1 - 10 of 556 | << page >> |