Narrow your search

Library

KU Leuven (53)

KBR (1)


Resource type

dissertation (53)


Language

English (40)

Dutch (12)

Undetermined (1)


Year
From To Submit

2024 (7)

2022 (4)

2021 (8)

2020 (7)

2019 (4)

More...
Listing 1 - 10 of 53 << page
of 6
>>
Sort by

Dissertation
Robot-assistance in total knee arthroplasty : procedure, registration and estimation of local bone properties
Authors: ---
ISBN: 9056826611 Year: 2005 Publisher: Heverlee Katholieke Universiteit Leuven. Faculteit Ingenieurswetenschappen

Loading...
Export citation

Choose an application

Bookmark

Abstract

Om bij een totale knie arthroplastie een correcte beweging van het kniegewricht en een lange levensduur van de prothese te verkrijgen, is een nauwkeurige positie en oriëntatie van de prothese vereist. Bovendien moet bij een niet-gecementeerde prothese het snijvlak zeer vlak zijn, om de botingroei mogelijk te maken die nodig is voor de fixatie op lange termijn. De huidige commercieel beschikbare robotsystemen voor totale knie arthroplastie verhogen de nauwkeurigheid van de interventie wel, maar hebben nog twee grote beperkingen. Ten eerste zijn de meeste van deze systemen actieve systemen, waarbij de rol van de chirurg beperkt is tot supervisie. Ten tweede is de meest gebruikte registratie-methode gebaseerd op het gebruik van preoperatief te plaatsen markers, wat een extra operatie vereist. Dit werk stelt vernieuwende technieken en procedures voor die een oplossing bieden voor deze nadelen. De technieken en procedures zijn uitgewerkt voor de tibia, vermits de meeste problemen bij totale knie arthroplastie daarmee gerelateerd zijn. Dit werk beschrijft de ontwikkeling en implementatie van een semi-actief robot systeem, gebaseerd op het gebruik van hybride kracht/snelheidscontrole. Hierbij bepaalt de chirurg de snelheid van de roboteindeffector door een kracht uit te oefenen op een handvat aan de robot, terwijl de robot de beweging beperkt tot het op voorhand gedefinieerde plan. Op deze manier houdt de chirurg de operatie onder controle en kan hij snel handelen indien nodig. Het robotsysteem is zo als het ware een chirurgisch instrument, dat de nauwkeurigheid van een frezende robot combineert met de ervaring van de chirurg. Freestesten uitgevoerd in laboratoriumomstandigheden tonen aan dat de frees-nauwkeurigheid van dit semi-actief systeem van dezelfde grootteorde is als dat van een actief systeem, en dat de verkregen vlakheid groter is dan bij de conventionele interventie. Ook tonen testen aan dat door de keuze van de freesparameters de temperatuur van het gefreesde bot binnen toegelaten grenzen kan blijven. Dit werk stelt twee alternatieve registratiemethoden voor die geen gebruik maken van markers, namelijk registratie met behulp van een intramedullaire pin en registratie gebaseerd op oppervlaktematching. Nauwkeurigheidstests en simulaties zijn uitgevoerd. Verder toont dit werk ook aan dat de freeskrachten een voorspellende waarde hebben voor de locale botkwaliteit. Hierdoor kan de chirurg zijn keuze van implantaattype, fixatietechniek en hoeveelheid bot die hij maximaal wil verwijderen, baseren op informatie uit de freeskrachten. A prerequisite for a successful total knee arthroplasty is a high accuracy of the position and orientation of the prosthesis, to obtain proper joint kinematics and a long lifetime of the prosthesis. Moreover, in case of a cementless fixation technique, a high surface flatness is essential for bone ingrowth and long-term fixation of the prosthesis. Current commercial robot systems for total knee arthroplasty improve the accuracy of the intervention but they have two major restrictions. First, most of them are active robot systems, limiting the role of the surgeon to supervision. Second, the prevalent registration method is based on the use of pre-operatively placed markers, implying an extra operation. This work proposes innovative techniques and procedures to overcome the aforementioned drawbacks. The preparation of the tibia is taken as a case study, because most problems in total knee arthroplasty are related to the tibial component. A semi-active robot system, using hybrid force/velocity control, is developed and implemented. In this system, the velocity of the end effector is proportional with the force that the surgeon exerts on a handle attached to the robot, while the robot constrains the motion to the predefined plan. In this way, the surgeon remains in charge of the intervention and can react swiftly to unexpected intra-operative events. Milling experiments in laboratory circumstances showed that the accuracy of a semi-actively milling robot is in the same order of magnitude as the accuracy of an autonomously milling robot, and that the surface flatness increases with respect to conventional surgery. Moreover, the temperature rise of the bone can be limited by constraining the milling parameters. With hybridforce/velocity control, the robot-system becomes a surgical tool, combining the accuracy of a milling robot, with the experience of the surgeon. To avoid the use of pre-operative markers, two registration methods for the tibia are developed: registration using an intramedullary rod and registration using surface matching. Accuracy tests and simulations show that these methods are an appropriate alternative to the registration method based on markers. This work shows further that the milling force has a predictive value for the bone mineral density. Therefore, the surgeon can use information from the milling forces to decide upon the maximal allowable removal of tibial bone, and to decide upon the choice of implant type or fixation technique. Robotondersteuning bij totale knie arthroplastie: procedure, registratie en schatting van lokale botkwaliteit. Totale knie arthroplastie (TKA) of vervanging van de gewrichtsoppervlakken van de knie door een prothese is de voornaamste behandeling voor mensen met ernstige kniegewrichtproblemen. Voor een lange levensduur van de prothese is het bij een TKA belangrijk dat de prothese nauwkeurig geplaatst wordt, zowel wat betreft de positie als de oriëntatie. Bovendien moet het snijvlak dat op het bot aangebracht wordt, zeer vlak zijn. Dit is vooral van belang bij een niet-gecementeerde prothese, omdat daarbij de fixatie op langere termijn afhangt van botingroei in het protheseoppervlak, en dat is enkel mogelijk bij een vlak snijvlak. Doordat robots de eigenschap hebben zeer nauwkeurig een vooraf gedefinieerde baan te volgen, werden robotsystemen ontwikkeld voor de orthopedische chirurgie. Momenteel zijn enkele robotsystemen op commerciële basis beschikbaar voor TKA. Deze robotsystemen verhogen de nauwkeurigheid van de interventie wel, maar hebben nog twee grote beperkingen. Ten eerste werken de meeste van deze systemen autonoom, waarbij de rol van de chirurg beperkt is tot supervisie. Ten tweede vereisen deze systemen een extra operatie, voorafgaand aan de eigenlijke ingreep. Dit werk stelt vernieuwende technieken en procedures voor om deze nadelen te verhelpen. Omdat de meeste problemen bij TKA gerelateerd zijn met het scheenbeen (de tibia), zijn deze technieken en procedures uitgewerkt voor de tibia. Het eerste gedeelte van dit werk stelt een semi-actief robotsysteem voor. Hierbij bepaalt de chirurg de snelheid van de roboteindeffector door een kracht uit te oefenen op een handvat aan de robot, terwijl de robot de beweging beperkt tot het op voorhand gedefinieerde vlak. Op deze manier houdt de chirurg de operatie volledig onder controle en kan hij snel handelen indien nodig.Dit type robotsysteem is als het ware een chirurgisch instrument, dat de nauwkeurigheid van een frezende robot combineert met de ervaring van de chirurg. Dit robotsysteem is gebaseerd op het gebruik van de 'hybride kracht/snelheidscontrole'. Freestesten uitgevoerd in laboratoriumomstandigheden tonen aan dat de nauwkeurigheid van dit semi-actief systeem van dezelfde grootteorde is als dat van een autonoom werkend robotsysteem, en dat de verkregen vlakheid groter is dan bij de conventionele interventie. Ook toont dit werk aan dat door een goede keuze van de freesparameters de temperatuur van het gefreesde bot binnen toegelaten grenzen blijft. Het tweede gedeelte van dit werk gaat op zoek naar alternatieven die de extraoperatie vermijden. Deze extra operatie is nodig wanneer de registratie (dit is het zoeken van het bot in de robotruimte) gebaseerd is op het gebruik van markers. Dit werk stelt twee toepasbare alternatieve registratiemethoden voor die geen gebruik maken van markers, namelijk registratie met behulp van een intramedullaire pin en registratie gebaseerd op oppervlaktematching. Nauwkeurigheidstests en simulaties zijn eveneens uitgevoerd. Het derde gedeelte van dit werk bekijkt specifiek de krachten die optreden bij het bewerken van het bot (frezen). Deze freeskrachten blijken een voorspellende waarde te hebben voor de lokale botkwaliteit. De informatie uit de freeskrachten, die tijdens de operatie aan de chirurg aangeboden wordt, kan de chirurg helpen in zijn keuze van implantaattype, fixatietechniek en hoeveelheid bot die hij maximaal wil verwijderen.


Dissertation
Mechanische analyse van de schroefbotverbinding bij pedikelschroeven

Loading...
Export citation

Choose an application

Bookmark

Abstract

Keywords


Dissertation
Developing and producing a 3D-printed functional transradial prosthesis in developing countries: feasability study.
Authors: --- ---
Year: 2024 Publisher: Leuven KU Leuven. Faculteit Industriële Ingenieurswetenschappen

Loading...
Export citation

Choose an application

Bookmark

Abstract

This thesis explores the feasibility of developing and producing a 3D-printed functional transradial prosthesis in developing countries, with the focus on Kenya. The research, done in collaboration with Ugani Prosthetics and the master’s program Innovative Health Technologies of the KU Leuven, addresses the challenges and potentials discovered while looking for a way to integrate 3D-printing in order to create affordable upper limb prosthetics. Despite the functional and infrastructural challenges, the research gives a clear view on the importance of iterative prototyping and feedback of the potential user. It creates a cultural lens in order to better understand the needs of this part of the world and gives insights into the technical, economic and social factors influencing prosthetic development in these constrained settings. The research lays the groundwork for future advancements and highlights the need for these types of medical innovations.

Keywords


Dissertation
Simulation and Prototyping of Floating Mass Transducers for Middle Ear Implants
Authors: --- ---
Year: 2024 Publisher: Leuven KU Leuven. Faculteit Industriële Ingenieurswetenschappen

Loading...
Export citation

Choose an application

Bookmark

Abstract

As hearing loss is becoming an increasing issue, new implantable hearing devices are developed. One of these implantable devices is the The Floating Mass Transducer (FMT). The FMT is a cylindrical hearing device that is implanted on one of the middle ear bones between the cochlea and the tympanic membrane. It works by vibrating at the same natural frequency as the middle ear bones, enlarging its amplitude in vibration, and thus increasing the signal to the cochlea. In this paper a study is performed to find out which parameters influence the behaviour of the FMT, and what needs to be taken into account to create a reproducible device. Five models at a 5:1 scale are designed, and a fully coupled simulation is made for the FMT. This simulation includes a coil and magnet interaction simulation, a spring constant calculation and a lumped mechanical system calculation. Using of the shelf materials, and 3D printing techniques, prototypes of the models are produced. The simulation made is validated using test results of the prototypes, and new models are designed using the simulation. The simulation and prototypes are compared using a velocity-frequency graph. A final model is presented which both in simulation and prototyping obtains as a result a velocity peak at a frequency that matches the middle ear.

Keywords


Dissertation
Intra-operative Assessment of Stability of Acetabular Implants – An in Vitro Preliminary Study

Loading...
Export citation

Choose an application

Bookmark

Abstract

Total Hip Arthroplasty is a common surgery for replacing impaired hip joints. One of the important steps in the procedure is to hammer the acetabular cup so that it is fixed in the pelvis. However, the depth of hammering is decided by the surgeon based on his or her experience. The fixation is crucial for evaluating the surgery: the pelvis might be fractured in case of too much hammering, this causes secondary injuring to the patient; if the fixation is insufficient, the acetabular cup could not be fixed properly. The research of the thesis is in the framework of finding this appropriate endpoint of insertion based on acoustic technology and will contain the evaluation of this new technique on foam block and animal bone models. By exciting the system, the generated sounds will be recorded. By using Fast Fourier Transform (FFT), the sound signals in time domain are transferred to the frequency domain. The resonance frequencies can be extracted. By observing the shift tendency of resonance frequencies. The end point of insertion will be determined. The experiments are conducted on six foam blocks and two bovine blocks. For the foam blocks, there are in total two sensitive resonance frequencies, the second one which varies from 1400 Hz to 2400 Hz turns out to be the most sensitive and the clearest, it can be used as the criterion to stop the insertion. For bovine blocks, the experiments are conducted on both one dried block without marrow and one moisturized block with marrow, the result on moisturized block with marrow is more clear than the result on dried one without marrow. This is a decent result since moisturized bovine block with marrow is closer to intra-operative situation. Both results on foam and bovine blocks indicate that the feature of resonance frequencies can be used as a criterion to stop the insertion, if resonance frequency stops around certain frequency for two or three times, this indicates the end of the insertion has been reached. However, the experiments have not been performed on in vivo situation, this could be done in the future work.

Keywords


Dissertation
Using torque-angle signatures to assess the Morse taper assembly in acetabular implants

Loading...
Export citation

Choose an application

Bookmark

Abstract

Total hip arthroplasty (THA) is nowadays one of the most common and successful orthopaedic interventions. Using THA implants consisting out of multiple components has become a popular and cost-effective way to offer customizable prostheses. However, implant modularity can increase the risk of complications leading to revision surgery. A Morse taper tightened by a locking screw is used in the acetabular component of some THA implants. The purpose of this study was to assess whether the quality of such Morse taper assembly could be tested by analysing the torque-angle signature of its locking screw. This characteristic curve is obtained when tightening the fastener. If successful, this method could be performed intraoperatively with minimal effects on the surgical technique. A model was created to predict the angular rotation of the locking screw until the torque would start to raise, depending on the thickness of the impingement. The experiments were performed using an electric motor to provide the torque, a torque cell to record it, and a digital encoder to track the angular rotation. Several layer types were interposed between the Morse taper surfaces of a modular acetabular THA implant, and the corresponding torque-angle signatures were measured. A series of features were extrapolated to compare the results. Increasing the thickness or the contact area of the layer had the main effect of reducing the number of rotations of the locking screw. While thinner layers confirmed the predicted angular values, thicker and more elastic layers showed deviations from the model. Two of the features defined proved to be an effective indicator of suboptimal Morse taper assemblies when interposing layers thicker than 100μm. Interposition of thinner layers could not be detected with a high degree of confidence by analysing torque-angle signatures. The results obtained depended on the specific geometry of the Morse taper and of the locking screw that were tested.

Keywords


Dissertation
Ontwikkeling en karakterisatie van hydraulische artificiële spieren voor precisie chirurgische instrumenten

Loading...
Export citation

Choose an application

Bookmark

Abstract

Het doel van deze thesis bestaat erin een hydraulisch alternatief te onderzoeken voor op dit moment bestaande pneumatische McKibben spieren en meer bepaald hun toepassingsmogelijkheden in chirurgische instrumenten te exploreren. Hydraulische spieren werden gebouwd, gekarakteriseerd en vergeleken met pneumatische versies die op dezelfde manier gemaakt werden. Een experimentele opstelling werd gebouwd die beoogt onder zo identiek mogelijke omstandigheden vergelijkende testen uit te voeren. De opstelling laat toe de verbanden tussen drie karakteristieke parameters te onderzoeken: kracht, druk en lengteverandering. Deze zullen resulteren in de volgende karakteristieken: kracht in functie van lengteverandering, lengteverandering in Naast grafische vergelijking van de desbetreffende karakteristieken werden mathematische modellen opgesteld die vergelijking van de overeenkomstige modelparameters toelaten. Het dynamische gedrag van de actuatiemetho berekend en vergeleken. De resultaten gaven weer dat hydraulische spieren vergelijkbare karakteristieken hebben waarbij de hydraulische versies meestal een betere herhaalbaarheid tonen. Tot slot werden een aantal prak verder onderzoek geschetst.

Keywords


Dissertation
Single-handed, flexible, steerable instruments for constrained workspace surgery
Authors: --- --- --- ---
Year: 2021 Publisher: Leuven KU Leuven. Faculty of Engineering Technology

Loading...
Export citation

Choose an application

Bookmark

Abstract

Minimally Invasive Surgery (MIS) is a modern surgical technique where surgeons operate through small incisions, called keyholes, rather than making large cuts to access the patient's organs. MIS is known to reduce patient trauma and shortens recovery time. To reach even lower levels of invasiveness, Natural Orifice Transluminal Endoscopic Surgery (NOTES) has been developed. In NOTES, specific sites are accessed by inserting instruments through natural orifices. While this procedure allows to limit the incisions to access the pathology, it also highly constrains the surgical workspace due to the geometric complexity of the human anatomy. Endoscopic maxillary sinus surgery is an example of such constrained workspace surgery. In endoscopic maxillary sinus surgery, the maxillary sinus is accessed through the nasal cavity which constitutes a narrow and tortuous pathway. Surgeons, however, still use rigid and straight or pre-bent instruments for this procedure which forces them to resect healthy tissues to access the pathology inside the maxillary sinus.This doctoral work aims at enhancing constrained workspace surgery by proposing new design and control strategies for flexible, steerable instruments. A further objective is to enable single-handed operation of these instruments. This allows the surgeon to be in full control of the operation while being able to use another instrument with his/her other hand.Finally, as the geometry of the natural orifice (i.e. the nasal cavity) varies to great extent for each patient and since developing patient-specific instruments would not be economical, a technique is developed to ensure coverage of a large share of the population. The resulting instrument provides the surgeon with an innovative miniature, intuitive, flexible instrument with enhanced dexterity while reducing the need to resect healthy tissues. The different research contributions at the origin of this work can be summarized in four points.First, a structured statistical shape model-based method was created from a series of patient's medical images of the targeted anatomy in order to derive the instrument specifications for a specific procedure. The proposed method is generic but was applied in this doctoral work to the maxillary sinus and the nasal cavity. It allowed to extract essential design-oriented data for the development of flexible instruments for endoscopic maxillary sinus surgery.Second, active add-ons intended to be coupled to commercial passive flexible endoscopes were designed. Those add-ons allow to improve the operation and control of otherwise passive commercial endoscopes. They also allow to speed up the development cycle of active flexible instruments. In this work, they have been used to evaluate the feasibility of single-handed flexible, steerable endoscopes for fetal surgery. They showed a good potential to ease surgical procedures by using flexible instruments.Third, an important step was made to further miniaturize McKibben-actuated surgical instruments. To do so, a novel miniature pneumatic actuator with integrated channel, called 'concentric muscle', has been designed and tested for integration in miniature flexible instruments. Moreover, open loop control methods were developed in order to provide accurate position control. This approach allows to avoid integration of distal position sensors and hence keep the instrument compact. More specifically, a hysteresis compensation algorithm was developed and tested to control the bending of a flexible fetoscope in open loop. The algorithm could successfully compensate for the pneumatic actuator hysteresis and friction in the instrument. A compact capacitance sensor was also designed for miniature artificial muscle actuators. The sensor predicts the muscle length with a 0.31mm precision over 80\% of the muscle's total contraction range. Lastly, a large displacement model was introduced. The model predicts the bending angle of a flexible Nitinol side-notched backbone with an accuracy of as low as $5.4^circ$ ($3.1 \%$). Those backbones are often use as a flexible distal tip in flexible surgical instruments.Fourth, a functional single-handed, steerable endoscope for flexible endoscopic maxillary sinus surgery has been designed and built using the previously mentioned contributions. This endoscope is the thinnest active flexible endoscope ever reported for maxillary sinus surgery, as far as the author is aware of. It was tested by two surgeons on a cadaver and showed an increased field of view in comparison to currently used instruments, which allowed limiting healthy tissue resection.This doctoral work provides tracks to enhance the miniaturization, flexibility and control of flexible instruments for constrained workspace surgery. Future directions are proposed to further enhance the here developed technology and make it available in the operating room. Such directions could consist in increasing the performance of the proposed actuators, sensors and control techniques, as well as investigating other types of instruments than flexible endoscopes, e.g. flexible graspers that require extra rigidity when grasping.

Keywords


Dissertation
Use of the “Woodpecker” instrument in total hip arthroplasty and determination of optimal fixation through sensor analysis

Loading...
Export citation

Choose an application

Bookmark

Abstract

This thesis explores avenues by which the incidence of fractures and loosely fitted femoral prostheses can be reduced in primary uncemented total hip arthroplasty. The impacts that insert the implant are used as excitation for vibrational analysis to simultaneously insert the implant and monitor the fixation. In addition we compare the quality of the insertion using either a hammer or the Woodpecker tool. Measurements are performed on a sawbone orthopaedic model. A fixation sensitive feature was found in the fractional bandpower in the 0 Hz to 1 kHz range. The fractional bandpower declines significantly to a value of less than 0.2 as fixation improves. The Woodpecker is shown to be unable to insert the implant to the same depth as the hammer.

Keywords


Dissertation
Comparison between different reaming techniques used to prepare artificial bone models for acetabular implant insertion

Loading...
Export citation

Choose an application

Bookmark

Abstract

Het heup gewricht ondergaat een cyclische belasting gedurende de dagelijkse activiteiten. Heupimplantaten, meer specifiek de bot-implantaat interface is onderhevig aan microbewegingen die kunnen leiden tot het lossen van het implantaat als kritische waarden van stabiliteit zijn overschreden. De initiële stabiliteit van niet-gecementeerde implantaten kan verhoogd worden door osseointegratie dat ervoor zorgt dat er bot groeit naar het implantaat. Bijkomend is een optimale perspassing nodig die genoeg contact oppervlakte vereist. De geometrie is bekomen door een chirurgische freeskop en de kwaliteit is sterk afhankelijk van de kwaliteit van het bot, de vaardigheid van de chirurg en de gebruikte machines. Een protocol werd ontworpen om een serie van polyurethaan blokjes te maken die het acetabulum voorsteld. Verschillende frees technieken zijn getest om een link te vinden tussen de gebruikte methode en de bekomen geometrie en oppervlakte ruwheid. Het idee hierachter is om een methodologie te bekomen om dit experiment in grotere aantallen te kunnen uitvoeren. Zo wordt het mogelijk gemaakt om een goede vergelijking te kunnen bekomen met de actuele resultaten bereikt tijdens een reële operatie. De geometrieën worden geëvalueerd door een aantal verschillende metingen. De meerderheid van de stukjes zijn digitaal gereconstrueerd door laser lijn scanning. Tijdens de postprocessing werden de stukjes vergeleken voor elke frees techniek. De best-fit sfeer is toegevoegd om de kwaliteit van de bekomen holtes te evalueren. De freeskop bepaalt de oppervlakte ruwheid en alle stukjes werden onderzocht door het gebruik van tactiel probe om relevante oppervlakte informatie te bekomen. De CNC-freesmachine maakt gebruik van een bal kop om met twee verschillende eindstappen de holte te frezen. De chirurgisch freeskop wordt gebruikt onder 3 omstandigheden: door een conventionele boorkolom, door een ervaren chirurg en door een onervaren hand. De resultaten wijzen aan dat de CNC gemaakte stukjes een nauwkeurigere dimensie hebben en vertonen ook de minste afwijking tegenover de ideale geometrie. De stukjes met de vrije hand gedaan of door de conventionele boorkolom laten een hogere afwijking zien. Naar de ruwheid kijkend, vertonen de CNC gemaakte stukjes een betere ruwheid en golving. Door het gebruik van de chirurgische freeskop onder de vernoemde omstandigheden, wordt een hogere ruwheid en golving zichtbaar door onvolkomenheden van het profiel. Om een link te bekomen tussen ruwheid, geometrie en initiële stabiliteit wordt een push-in en push-uit test gedaan met één soort van implantaat. Het is niet de meest voorkomende manier om de initiële stabiliteit te bekomen, maar het geeft wel een eerste indicatie. Test van microbewegingen, die de relatieve beweging meten van het implantaat tegenover de holte zijn een betere indicatie en wordt aangeraden in vervolgonderzoek. Deze resultaten tonen aan dat de push-in en push-out test geen voldoende indicatie kunnen geven over de initiële stabiliteit. Aangezien er telkens een andere freestechniek gebruikt wordt, veranderen er meerdere parameters. Deze parameters beïnvloeden elkaar en kan er geen éénduidige conclusie gemaakt worden. Meerdere tests zijn dus aangeraden in een vervolgonderzoek.

Keywords

Listing 1 - 10 of 53 << page
of 6
>>
Sort by