Narrow your search

Library

KU Leuven (2)


Resource type

dissertation (2)


Language

Dutch (1)

English (1)


Year
From To Submit

2024 (2)

Listing 1 - 2 of 2
Sort by

Dissertation
Benefits of automated gross tumor volume segmentation in head and neck cancer using multi-modality information

Loading...
Export citation

Choose an application

Bookmark

Abstract

Purpose: Gross tumor volume (GTV) delineation for head and neck cancer (HNC) radiation therapy planning is time consuming and prone to interobserver variability (IOV). The aim of this study was (1) to develop an automated GTV delineation approach of primary tumor (GTVp) and pathologic lymph nodes (GTVn) based on a 3D convolutional neural network (CNN) exploiting multi-modality imaging input as required in clinical practice, and (2) to validate its accuracy, efficiency and IOV compared to manual delineation in a clinical setting. Methods: Two datasets were retrospectively collected from 150 clinical cases. CNNs were trained for GTV delineation with consensus delineation as ground truth, with either single (CT) or co-registered multi-modal (CT + PET or CT + MRI) imaging data as input. For validation, GTVs were delineated on 20 new cases by two observers, once manually, once by correcting the delineations generated by the CNN. Results: Both multi-modality CNNs performed better than the single-modality CNN and were selected for clinical validation. Mean Dice Similarity Coefficient (DSC) for (GTVp, GTVn) respectively between automated and manual delineations was (69%, 79%) for CT + PET and (59%,71%) for CT + MRI. Mean DSC between automated and corrected delineations was (81%,89%) for CT + PET and (69%,77%) for CT + MRI. Mean DSC between observers was (76%,86%) for manual delineations and (95%,96%) for corrected delineations, indicating a significant decrease in IOV (p < 10-5), while efficiency increased significantly (48%, p < 10-5). Conclusion: Multi-modality automated delineation of GTV of HNC was shown to be more efficient and consistent compared to manual delineation in a clinical setting and beneficial over a single-modality approach.

Keywords


Dissertation
Whole-body dMRI With EPI Distortion Correction: A Prospective Cross-sectional Observational Study

Loading...
Export citation

Choose an application

Bookmark

Abstract

Whole-body diffusion weighted imaging (WBDWI) wordt vaak uitgevoerd, maar is onderhevig aan vervormingen door het gebruik van single-shot echo planar imaging (SS-EPI)-acquisitietechnieken. Een inline SS-EPI-correctiemethode (EPIC) is beschikbaar voor hersenscans, maar niet voor WBDWI. Deze masterproef onderzoekt EPIC in de context van WBDWI. Eerst wordt een aangepast scanprotocol gemaakt met EPIC. Ten tweede worden drie gezonde vrijwilligers gescand. Ten derde worden de beelden van gezonde vrijwilligers kwantitatief geëvalueerd en vergeleken op basis van de volgende kenmerken: apparent diffusion coëfficiënt (ADC)-waarden, signaal-ruisverhouding (SNR), positie van het ruggenmerg, inter-station uitlijning, en similariteit. Na en tijdens de evaluatie van de beelden wordt het protocol geoptimaliseerd. Het maximale verschil in ADC-waarden is kleiner dan 4,5%. SNR-stijgingen en dalingen tot respectievelijk 58% en 13% zijn gemeten. EPIC vermindert de vervorming van het spinale kanaal met gemiddeld 60% en verbetert de uitlijning tussen stations met gemiddeld 51%. Mutual information van gecorrigeerde beelden is gemiddeld 0,037 hoger dan bij ongecorrigeerde beelden, ten aanzien van T2-beelden. De conclusie is dat EPIC de ADC-waarden van weefsels niet noemenswaardig verandert maar de SNR kan verhogen of verlagen. De uitlijning tussen stations, spinaalkanaalvervorming, en similariteit verbeteren door EPIC. Een gericht whole-body scanprotocol met EPIC is gemaakt, dat verder gebruikt kan worden om te testen op een klinische populatie.

Keywords

Listing 1 - 2 of 2
Sort by