The title is updated to reflect a trial-use guide and two misspelled names in the participants list and a number in Equation (29) are corrected in this corrigendum.
Choose an application
Choose an application
Choose an application
This part of IEC 62271 applies to all overhead, pad-mounted, dry vault and submersible single or multi-pole alternating current automatic circuit reclosers for rated maximum voltages above 1 000 V and up to and including 38 kV. Devices that require a dependent manual operation are not covered by this document. In order to simplify this document where possible, the term recloser (or reclosers) has been substituted for automatic circuit recloser(s) or cutout mounted recloser(s) or both.
Electric switchgear --- Electric circuit-breakers --- Electric circuits --- Standards. --- Alternating current.
Choose an application
This standard is applicable to ac circuit switchers designed for outdoor installation and for rated power frequencies of 50 Hz and 60 Hz and rated maximum voltages of 15.5 kV through 245 kV. It is applicable only to three-pole circuit switchers for use in three-phase systems. This standard is also applicable to the operating devices of circuit switchers and to their auxiliary equipment. Included in this document are the normal and special service conditions under which the ratings are based and requirements for design and construction, which include those for interrupting media, stored energy systems, operating characteristics, mechanical loading and operation capabilities, electrical insulation, and auxiliary devices. The rating structure establishes the basis for all assigned ratings, including continuous current, dielectric withstand voltages, primary-bus fault breaking current, transformer-limited fault breaking current, short-circuit making current, transient recovery voltages, and capacitor switching, plus associated capabilities such as mechanical endurance and operation under high- and low-temperature environmental extremes. Routine (production) tests are defined and requirements for their execution documented.
Electric switchgear --- Electric circuits --- High voltages. --- Standards. --- Alternating current.
Choose an application
Electric circuits --- Energy consumption --- Electric networks. --- Alternating current.