Listing 1 - 10 of 20 | << page >> |
Sort by
|
Choose an application
Very low frequency (VLF) withstand and other diagnostic tests and measurements that are performed using VLF energization in the field on shielded power cable systems are described in this guide. Whenever possible, cable systems are treated in a similar manner to individual cables. Tables are included as an aid to identifying the effectiveness of the VLF ac voltage test for various cable system insulation problems. Keywords: cable fault locating, cable system testing, cable testing, condition assessment, dielectric spectroscopy, grounding, hipot testing, IEEE 400.2, partial discharge testing, proof testing, safety, tangent delta testing, very low frequency testing, VLF ac voltage testing.
Choose an application
Very low frequency (VLF) withstand and other diagnostic tests and measurements that are performed using VLF energization in the field on shielded power cable systems are described in this guide. Whenever possible, cable systems are treated in a similar manner to individual cables. Tables are included as an aid to identifying the effectiveness of the VLF ac voltage test for various cable system insulation problems.
Choose an application
Guidance for the design and installation of cable raceway systems for all types of electric generating facilities is provided. Recommendations, methods, and best engineering practices for the design of cable raceway systems including selection of equipment, materials, and the configuration of raceway are described.
Choose an application
Procedures and test voltage values for acceptance and maintenance testing of electric submersible pump (ESP) cable systems are presented. This recommended practice applies to cable systems rated 3 kV and 5 kV (phase to phase) and is intended only for this special-purpose cable. The intent is to provide uniform test procedures and guidelines for evaluation of the test results.
Choose an application
Procedures and test voltage values for acceptance and maintenance testing of electric submersible pump (ESP) cable systems are presented. This recommended practice applies to cable systems rated 3 kV and 5 kV (phase to phase) and is intended only for this special-purpose cable. The intent is to provide uniform test procedures and guidelines for evaluation of the test results.
Choose an application
Corrections to the introduction for the standard with over 3000 ampacity tables for extruded dielectric power cables rated through 138 kV and laminar dielectric power cables rated through 500 kV are addressed in this amendment.
Choose an application
Basic factors and general considerations in selecting the class and means of neutral grounding for electrical generating plant auxiliary power systems are given in this guide. Apparatus to be used to achieve the desired grounding are suggested, and methods to specify the grounding devices are given. Sensitivity and selectivity of equipment ground-fault protection as affected by selection of the neutral grounding device are discussed, with examples.
Choose an application
In this book the reader will find a collection of chapters written by different experts around the world, describing the current research trends in both short- and long-period fiber grating technology. This work is mainly addressed to researchers already working in this area, but it is also accessible to anyone with a scientific background who desires to have an updated overview of the recent progress in this domain. It will also be valuable to scientist and engineers who have become newly involved in this field. Each chapter is self-contained and can be read independently of the others. This book intends to provide highlights of the current research in this area, showing the recent advances in the field of fiber gratings.
Fiber optic cables. --- Fiber optics --- Telecommunication cables --- Applied optics
Choose an application
Minimum requirements for the design, construction, manufacturing, testing, purchasing, and application of electric submersible pump (ESP) cable are presented. The cable is round or flat, with ethylene-propylene rubber insulation, nitrile jacket, ethylene-propylene diene monomer (EPDM) jacket or lead sheath, and armor. These cables are for voltages not exceeding 3 kV or 5 kV (phase to phase) and conductor temperatures not exceeding 140 ºC (284 ºF) for nitrile or a maximum of 232 ºC (450 ºF) for EPDM jacket or lead sheath cable. Conductors, insulation, barrier (optional), assembly with or without jacket, armor, requirements for testing by the manufacturer, and cable ampacity are all covered in the document.
Choose an application
Minimum requirements for the design, construction, manufacturing, testing, purchasing, and application of electric submersible pump (ESP) cable are presented. The cable is round or flat, with ethylene-propylene rubber insulation, nitrile jacket, ethylene-propylene diene monomer (EPDM) jacket or lead sheath, and armor. These cables are for voltages not exceeding 3 kV or 5 kV (phase to phase) and conductor temperatures not exceeding 140 ºC (284 ºF) for nitrile or a maximum of 232 ºC (450 ºF) for EPDM jacket or lead sheath cable. Conductors, insulation, barrier (optional), assembly with or without jacket, armor, requirements for testing by the manufacturer, and cable ampacity are all covered in the document.
Listing 1 - 10 of 20 | << page >> |
Sort by
|