Narrow your search
Listing 1 - 10 of 40 << page
of 4
>>
Sort by

Book
IEEE Std C57.106-2002 (Revision of IEEE Std C57.106-1991) : IEEE Guide for Acceptance and Maintenance of Insulating Oil in Equipment
Author:
ISBN: 0738133191 0738133205 Year: 2002 Publisher: New York : IEEE,

Loading...
Export citation

Choose an application

Bookmark

Abstract

This IEEE Standards product is part of the C57 family on Power Distribution and Regulating Transformers. Abstract: Recommendations regarding oil tests and evaluation procedures are made in this guide;references are made to methods of reconditioning and reclaiming conventional petroleum (mineral) dielectric insulating oils;the levels at which these methods become necessary; and the routines for restoring oxidation resistance, where required, by the addition of oxidation inhibitors. The intent is to assist the power equipment operator in evaluating the serviceability of oil received in equipment, oil as received from the supplier for lling new equipment at the installation site, and oil as processed into such equipment; and to assist the operator in maintaining oil in serviceable condition. The mineral oil covered is used in transformers, reactors, circuit breakers, load tap changers, and voltage regulators. Keywords :insulation testing , load tap changers , oil circuit breakers , oil insulation , power distribution maintenance , power transformer insulation , reactors , transformers , voltage regulators , IEEE C57.106.


Book
C57.19.01-2000 IEEE Standard Performance Characteristics and Dimensions for Outdoor Apparatus Bushings
Author:
ISBN: 0738119849 0738119857 Publisher: [Place of publication not identified] IEEE

Loading...
Export citation

Choose an application

Bookmark

Abstract

Superseded by C57.19.01-2000 Electrical, dimensional, and related requirements for outdoor power-class apparatus bushings that have basic impulse insulation levels of 110 kV and higher are covered. Specific values for dimensional and related requirements that are to be interpreted, measured, or tested in accordance with IEEE C57.19.00-1991 are provided. Bushings covered by this standard are intended for use as components of oil-filled transformers, oil-filled reactors, and oil circuit breakers.


Book
Insulators
Author:
ISBN: 1611223962 9781611223965 9781617619960 1617619965 Year: 2011 Publisher: New York

Loading...
Export citation

Choose an application

Bookmark

Abstract


Periodical
Annual report conference on electrical insulation and dielectric phenomena

Loading...
Export citation

Choose an application

Bookmark

Abstract


Book
Proceedings, Electrical Insulation Conference and Electrical Manufacturing Conference : Indiana Convention Center, Indianapolis, Indiana, October 23-26, 2005
Authors: --- --- ---
ISBN: 0780391454 1538601575 9781538601570 Year: 2005 Publisher: [Place of publication not identified] IEEE

Extended abstracts of the international workshop on gate insulator IWGI 2001.
ISBN: 4891140216 Year: 2001 Publisher: Tokyo Business Center for Academic Societies


Book
IEEE standard for transformers : underground-type, self-cooled, single-phase distribution transformers with separable, insulated, high-voltage connectors ; high voltage (24 940 GrdY/14 400 v and below) and low-voltage (240/120 v, 167 kVA and smaller).
Author:
ISBN: 0738134759 Year: 1992 Publisher: New York : IEEE,

Loading...
Export citation

Choose an application

Bookmark

Abstract

Electrical, dimensional, and mechanical characteristics and certain safety features of single-phase, 60 Hz, mineral-oil-immersed, self-cooled, distribution transformers with separable insulated high-voltage connectors are covered. Ratings, testing, and construction are discussed. These transformers are generally used for step-down pruposes from an underground primary cable supply and are suitable for occasional submerged operation. The intent is to provide a basis for determining their performance, interchangeability, and safety, and for their selection. This standard does not cover the electrical and mechanical requirements of accessory devices that may be supplied with the transformer.


Book
IEEE standard test procedure for thermal evaluation of systems of insulating materials for random-wound AC electric machinery.
Author:
ISBN: 1504438817 Year: 2016 Publisher: New York : IEEE,

Loading...
Export citation

Choose an application

Bookmark

Abstract

The standard test procedure for the thermal evaluation and qualification of electrical insulation systems (EISs) for random-wound ac electric machinery, where thermal degradation is the dominating aging factor, is described. The relative thermal performance of a candidate EIS is compared to that of a reference EIS. Insulation systems for such machinery with input voltage of up to 600 V at 50/60 Hz are described in this standard. A statistical method for establishing a relative life-temperature relationship for an insulation system is also described. To have any significance, the reference insulation system must be supported with adequate field service data. Evaluation of insulation systems for use in air-cooled, random-wound ac electric machinery with usual service conditions is this procedure s intent. This procedure, on its own, does not cover insulation systems such as exposure to conducting contaminates, radiation, inverter applications, or operation in oils, refrigerants, or other media that potentially degrades insulating materials.


Book
Simulation and Modelling of Electrical Insulation Weaknesses in Electrical Equipment
Authors: ---
ISBN: 1789237696 1789237688 1838816852 Year: 2018 Publisher: IntechOpen

Loading...
Export citation

Choose an application

Bookmark

Abstract

Around 80% of electrical consumption in an industrialised society is used by machinery and electrical drives. Therefore, it is key to have reliable grids that feed these electrical assets. Consequently, it is necessary to carry out pre-commissioning tests of their insulation systems and, in some cases, to implement an online condition monitoring and trending analysis of key variables, such as partial discharges and temperature, among others. Because the tests carried out for analysing the dielectric behaviour of insulation systems are commonly standardised, it is of interest to have tools that simulate the real behaviour of those and their weaknesses to prevent electrical breakdowns. The aim of this book is to provide the reader with models for electrical insulation systems diagnosis.

High voltage vacuum insulation
Author:
ISBN: 1281038342 9786611038342 0080533973 0124371752 9780124371750 9780080533971 9781281038340 6611038345 Year: 1995 Publisher: London San Diego Academic Press

Loading...
Export citation

Choose an application

Bookmark

Abstract

The past decade has witnessed dramatic growth in the diversity and complexity of device applications where vacuum is required to support either high voltages or high electric fields. This is particularly true in the space industry, specifically for the development of space-based pulse power systems.This book presents an overview of the technological advances that have occurred since the publication of the Editors earlier book High Voltage Vacuum Insulation: The Physical Basis. In this latest book, contributions from internationally recognized professionals and researchers in the

Listing 1 - 10 of 40 << page
of 4
>>
Sort by