Gas-insulated transmission lines (GIL) is an established high voltage technology used when environmental or structural considerations restrict the use of overhead transmission lines. With an overview on the technical, economical and environmental impact and power system implications of GIL, this guide provides a complete understanding of its physical design, features and advantages. The author illustrates how to evaluate when GIL would be the best solution during the planning sequence and how to apply GIL in the electricity power network.Other key features include:. operation and maintenance requirements with information on repair processes, duration, and different monitoring systems enabling the achievement of reliable and safe operation;. a wide variety of realized applications from across the world over the past 35 years, illustrating typical fields of application through descriptions of real projects that the author has worked on; and. future application possibilities in a smart transmission network, used for solving power transmission problems.This is an essential reference for engineers involved in planning and executing bulk power transmission projects overground, in tunnels or buried. It offers a concise summary of all areas of the subject and is the perfect aid for utility power engineers, consulting engineers and manufacturers worldwide.
Choose an application
Choose an application
Gas-insulated transmission lines (GIL) is an established high voltage technology used when environmental or structural considerations restrict the use of overhead transmission lines. With an overview on the technical, economical and environmental impact and power system implications of GIL, this guide provides a complete understanding of its physical design, features and advantages. The author illustrates how to evaluate when GIL would be the best solution during the planning sequence and how to apply GIL in the electricity power network.Other key features include:. operation and maintenance requirements with information on repair processes, duration, and different monitoring systems enabling the achievement of reliable and safe operation;. a wide variety of realized applications from across the world over the past 35 years, illustrating typical fields of application through descriptions of real projects that the author has worked on; and. future application possibilities in a smart transmission network, used for solving power transmission problems.This is an essential reference for engineers involved in planning and executing bulk power transmission projects overground, in tunnels or buried. It offers a concise summary of all areas of the subject and is the perfect aid for utility power engineers, consulting engineers and manufacturers worldwide.
Choose an application
The technical requirements fot the design, fabrication, testing, and installation of a gas-insulated substations (GIS) are covered. The parameters to be supplied by the purchaser are set, and the technical requirements for the design, fabrication, testing, and installation to be furnished by the manufacturer are established.
Electric substations. --- Electric cables --- Gas insulation.
Choose an application
The technical requirements for the design, fabrication, testing, and installation of a gas-insulated substation (GIS) are covered. Parameters to be supplied by the purchaser are suggested, and technical requirements for the design, fabrication, testing, and installation to be furnished by the manufacturer are established.
Electric substations. --- Electric cables --- Gas insulation.
Choose an application
Information of special relevance to planning, design, testing, installation, operation and maintenance of gas-insulated substations (GIS) and equipment is provided in this guide, which is intended to supplement IEEE Std C37.122(TM). This guide is applicable to all gas-insulated substations (GIS) above 52 kV. However, the importance of topics covered varies with application category. For example, the issues related to advanced field test techniques and very fast transients (VFT) are of particular interest for extra-high voltage (EHV) gas-insulated substations (GIS).
Electric substations. --- Electric cables --- Gas insulation.
Choose an application
Information of special relevance to planning, design, testing, installation, operation and maintenance of gas-insulated substations (GIS) and equipment is provided in this guide, which is intended to supplement IEEE Std C37.122™. This guide is applicable to all gas-insulated substations (GIS) above 52 kV. However, the importance of topics covered varies with application category. For example, the issues related to advanced field test techniques and very fast transients (VFT) are of particular interest for extra-high voltage (EHV) gas-insulated substations (GIS).
Electric substations. --- Electric cables --- Gas insulation.
Choose an application
The technical requirements for the design, fabrication, testing, and installation of indoor gas-insulated substations (GIS) 1 kV up to 52 kV are covered. Parameters to be supplied by the purchaser are suggested and technical requirements for the design, fabrication, testing, and installations to be furnished by the manufacturer are established.
Electric substations. --- Electric cables --- Gas insulation.
Choose an application
Recommendations for the connection of gas-insulated substation to another gas-insulated substation of a different make or design are given. IEEE Std 1416TM is replaced by this recommended practice.
Electric cables --- Electric substations. --- Gas insulation.
Choose an application
Recommendations for the connection of gas-insulated substation to another gas-insulated substation of a different make or design are given. IEEE Std 1416TM is replaced by this recommended practice.
Electric cables --- Electric substations. --- Gas insulation.